How to inject with the GONAL-f RFF Redi-ject pen
This guide takes you through injecting with the GONAL-f RFF Redi-ject prefilled pen, one step at a time. It covers 8 stages, from taking the pen out of the fridge to recapping it after your injection.
What the guide covers
1Getting ready6 steps
Take the pen out of the fridge
Take the carton out of the refrigerator at least 30 minutes before you inject to let it warm to room temperature.
Do not use a microwave or other heating element to warm up the pen.
Set up your space
Prepare a clean, flat surface, such as a table or countertop, in a well-lit area.
Gather your supplies
You will also need a sharps disposal container, alcohol pads, and a writing utensil (not included).
Wash your hands
Wash your hands with soap and water and dry them well.
Do not shake the pen. If you shake the pen, air bubbles may appear in the medicine.
Take out the pen and a new needle
Remove the pen and a new needle from the carton using your hands.
Do not use any tools (such as a knife, scissors or box cutters) to take the pen out of the carton because they may damage the pen.
Check the name and the expiration date
Check that the name on the pen says GONAL-f RFF Redi-ject. Check the expiration date on the pen label.
2Injection site1 step
Choose and clean the injection site
Select your injection site and wipe the skin with an alcohol pad to clean the site.
Do not blow on or touch the injection site after cleaning.
3Attach the needle4 steps
Pull off the pen cap and check the medicine
Pull off the pen cap. Make sure the plastic reservoir that holds the medicine is not cracked. Confirm the medicine is clear, colorless, and does not contain particles.
Take a new needle and check its seal
Get a new needle. Only use the single-use needles supplied. Re-using needles can cause infection. Check that the needle's peel-off seal tab is not broken. If it is, get a new needle.
Do not use the needle if it is damaged, expired or if the outer needle cap or peel-off seal tab is damaged or loose. This can lead to an infection. Throw it away in a sharps disposal container and get a new needle.
Attach the needle
Peel off the needle seal. Push the needle on the clear, plastic end of the pen, and twist the needle until you cannot twist it anymore.
Do not attach the needle too tightly, the needle could be difficult to remove after the injection.
Remove the outer cap and inner shield
Pull off the outer needle cap and save it for removing the needle after the injection. Keeping the needle pointing up, carefully pull off the inner needle shield and throw it away.
Do not recap the needle with the inner needle shield, or you could get a needle stick injury.
4First use of a pen1 step
New pen? Check for a droplet
Only if it applies.
If you do not see a droplet of liquid on the tip of the needle when using a pen for the first time, turn the dose knob until the Dose Information Display reads "25". With the needle pointing up, gently tap the reservoir so that any air bubbles rise to the top. Hold the pen with the needle pointing up. Slowly press the dose knob in all the way. One or more tiny drops of liquid will appear at the tip of the needle. Release the dose knob. Make sure that the Dose Information Display reads "0". If a droplet of liquid does not appear, contact your healthcare provider.
5Dial the dose2 steps
Dial your dose
Turn the dose knob until your intended dose shows in the Dose Information Display.
Do not push or pull the dose knob while you turn it to avoid damaging it.
Match the display to your diary
Make sure the Dose Information Display matches the intended dose recorded in Column 5 in your treatment diary.
6Inject2 steps
Push the needle in at 90 degrees
Hold the pen at a 90° angle to the injection site, and push the needle into your skin.
You might bend the needle if you do not insert the needle straight in at a 90° angle.
Press the dose knob and count to 5
Place your thumb in the middle of the dose knob. Use your thumb to slowly press the dose knob straight down as far as it will go.
Do not release the dose knob until you remove the needle from your skin. Hold the dose knob down for a slow count of 5 before you remove the needle from your skin. Then release the dose knob after removal of the needle from your skin.
7Right after2 steps
Remove the needle and release the knob
Remove the needle from your skin, release the dose knob, and put the pen on the table.
Does the display show 0?
After injecting, fill in "Yes" or "No" in Column 6 of the treatment diary, to record if the Dose Information Display shows "0".
8Tidying up3 steps
Recap the needle with one hand
Lay the outer needle cap on its side on a flat surface. Hold the pen with the needle attached in one hand, and slip the needle into the outer needle cap without using your other hand.
Click the cap on and twist the needle off
Push the capped needle against a firm, vertical surface, such as a GONAL-f RFF Redi-ject carton or a wall, until you hear a "click". Twist off the capped needle and throw it away in a FDA-cleared sharps disposal container.
Recap the pen and record your injection