Injection guide · Organon LLC

How to inject FOLLISTIM AQ with the FOLLISTIM Pen

This guide takes you through loading a FOLLISTIM AQ Cartridge into the FOLLISTIM Pen and giving the injection, one step at a time. It covers 7 stages, from taking the cartridge out of the fridge to disposing of your needle.

What the guide covers

  1. 1Getting ready4 steps
    1. Take the cartridge out of the fridge

      Remove the FOLLISTIM AQ Cartridge out of the refrigerator. Injecting cold medicine can cause discomfort at the injection site. Allow the FOLLISTIM AQ Cartridge to reach room temperature before injecting.

    2. Check the liquid in the cartridge

      Check the liquid in the cartridge to make sure it is clear and colorless. Do not use, if the liquid is not clear and colorless or has particles in it.

    3. Gather your supplies

      Gather the supplies you will need for your injection. You will need: a clean dry surface FOLLISTIM Pen FOLLISTIM AQ Cartridge BD Micro-Fine Pen Needle alcohol pads cotton balls or sterile gauze a puncture-proof container to throw away the used cartridge and needle

    4. Wash your hands

      Wash your hands with soap and water and dry them before you use FOLLISTIM Pen and when you replace the cartridge.

  2. 2Loading the pen7 steps
    1. Pull off the protective cap

      Hold the FOLLISTIM Pen Body firmly with one hand. With the other hand, pull the Protective Cap straight off with your other hand (See Figure 4). Put the cap aside on a clean, dry surface.

    2. Unscrew the pen body from the cartridge holder

      Unscrew the Pen Body from the Cartridge Holder (See Figure 5). Place the Cartridge Holder and the Pen Body aside.

    3. Clean the cartridge and put it in the holder

      Take the FOLLISTIM AQ Cartridge out of the package. Clean the rubber inlay on the cartridge with an alcohol pad. Put the FOLLISTIM AQ Cartridge into the Cartridge Holder (See Figure 6). The metal rimmed cap goes in first.

    4. Screw the pen body onto the holder

      Insert the Pen Body into the Cartridge Holder. The black rod must press against the Rubber Piston on the cartridge. Screw the Pen Body fully onto the Cartridge Holder (See Figure 7). Make sure there is no gap between the Pen Body and the Cartridge Holder. The arrow ( ) on the Cartridge Holder should point to the middle of the yellow alignment mark ( ) on the Pen Body.

    5. Clean the open end of the holder

      Clean the open end of the Cartridge Holder with an alcohol pad (See Figure 8).

    6. Take a new pen needle

      Pick up a new BD Micro-Fine Pen Needle that is in its Outer Needle Shield. Peel off the protective paper seal (See Figure 9). Do not touch the needle. Do not place the open needle on any surface. Use only the BD Micro-Fine 0.33 mm × 12.7 mm (29G) Pen Needles as supplied with the FOLLISTIM AQ Cartridge. Use a new BD Micro-Fine Pen Needle with each injection. Never reuse a needle. Attach a new BD Micro-Fine Pen Needle after you make sure there is a FOLLISTIM AQ Cartridge in the Cartridge Holder.

    7. Screw the needle on

      Hold the Outer Needle Shield firmly in one hand while holding the Cartridge Holder firmly in the other hand. Push the end of the Cartridge Holder into the Outer Needle Shield. Screw them tightly together (See Figure 10). Place your FOLLISTIM Pen aside.

  3. 3Injection site2 steps
    1. Where to inject

      When giving a subcutaneous injection, follow your healthcare provider’s instructions about changing the site for each injection. This will help lower your chances of having a skin reaction. The recommended sites for injecting FOLLISTIM AQ Cartridge are: just below your belly button (navel) (See Figure 11) the upper outer area of your thigh (See Figure 12)

      Do not inject FOLLISTIM AQ Cartridge into an area that is tender, red, bruised, or hard.

    2. Clean the site

      Choose an injection site. Clean the skin at the injection site with an alcohol wipe. Clean about two inches around the injection site where the needle will be inserted. Do not touch the cleaned area of skin.

  4. 4Check the flow and dial4 steps
    1. Pull off the outer needle shield and keep it

      Hold the FOLLISTIM Pen and pull off the outer needle shield. Leave the Inner Needle Shield in place over the needle attached to the Pen (See Figure 13). Do not throw away the Outer Needle Shield, you will need it later when you throw away the needle.

    2. Remove the inner shield and tap out air

      Carefully remove the Inner Needle Shield and throw it away (discard) (See Figure 14). Do not touch the needle or let the needle touch any surface while uncapped. Hold the FOLLISTIM Pen with the needle pointing upwards. Tap the Cartridge Holder gently with your finger to help air bubbles rise to the top of the needle. The small amount of air bubbles will not affect the amount of medicine you receive.

    3. Check the flow: look for a droplet

      With an unused cartridge loaded: Dial the Dosage Knob until you hear 1 click. With the needle pointing upwards, push in the Injection Button. Look for a droplet of medicine at the tip of the needle (See Figure 15). If you see the droplet, then you can dial in your dose. If you do not see a droplet, repeat number 1 (above) until you see droplet.

      You must make sure you see a droplet of medicine (check the flow of medicine) or you may not inject the correct dose amount.

    4. Dial your dose

      For doses of 50 IU up to 450 IU, turn the Dosage Knob until the correct dosage aligns with the dosage markers on each side of the Dosage Window (See Figure 16).

      Never dial your dose or try to correct a dialing mistake when the needle is still in your skin. You may receive an incorrect dose.

  5. 5Inject2 steps
    1. Pinch the skin and insert the needle

      Pinch a fold of skin at the cleaned injection site with one hand. Do not touch the cleaned area of skin. With the other hand hold the FOLLISTIM Pen with FOLLISTIM AQ Cartridge loaded and BD Micro-Fine Needle. Use a quick “dart-like” motion to insert the needle straight up and down (90° angle).

    2. Press the button all the way and wait 5 seconds

      Press the injection button all the way in to make sure you give yourself a full injection (See Figure 18). Wait for 5 seconds before pulling the needle out of the skin. The middle of the Dosage Window should display a dot next to the "0".

  6. 6Right after1 step
    1. Remove the needle and press the site

      Remove the BD Micro-Fine Needle from your skin and firmly press down on the injection site with an alcohol swab. Be very careful when handling the needle. If you are giving an injection to another person, accidental needle sticks with used needles can cause serious infections or infections that may lead to death.

  7. 7Tidying up4 steps
    1. Recap the needle without holding the shield

      Carefully follow these instructions. Place the Outer Needle Shield on a flat table surface with the opening pointing up. The opening of the Outer Needle Shield is the wider end with the rim. Without holding on to the Outer Needle Shield, carefully insert the needle (attached to the FOLLISTIM Pen) straight into the center of the opening of the Outer Needle Shield and push down firmly (See Figure 19). Be sure the Outer Needle Shield is completely covering the entire needle.

    2. Unscrew the needle and throw it away

      Grip the Outer Needle Shield carefully and use it to unscrew the needle from the Cartridge Holder (See Figure 20). Throw away the Outer Needle Shield with the used needle right away. Do not throw away in a trash can. (See “How Do I Throw Away Used Cartridges and Needles?”)

    3. Medicine left in the cartridge?

      Only if it applies.

      If there is medicine left in the FOLLISTIM AQ Cartridge for more injections, put the Pen Cap back on the Pen Body and store your FOLLISTIM Pen in a safe place in the refrigerator (not in the freezer) or at room temperature. Never store the FOLLISTIM Pen with a needle attached to it. Unscrew the Pen Body from the Cartridge Holder with the empty FOLLISTIM AQ Cartridge (See Figure 21). Remove the empty FOLLISTIM AQ Cartridge from the Cartridge Holder (See Figure 22). Safely, throw away (dispose of) the empty FOLLISTIM AQ Cartridge right away. Do not put the cartridge in your household trash. (See “How Do I Throw Away Used Cartridges and Needles?”)

    4. Into the sharps container

      Put your used cartridges and needles in an FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) loose needles and cartridges in your household trash.